Placa de inducción de 3 fuegos

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
-
Do not install the induction hob directly over a dishwasher, a refrigerator, a freezer, a
washing machine, or a dryer, as moisture could damage the electric system of the hob.
-
The induction hob must be installed in a manner that ensures the best heat radiation to
obtain the best results.
-
The wall and the area over the work surface must be heat resistant.
-
To avoid any damage, the bonding layer and the adhesive must be heat resistant.
Connecting the hob to the mains
Fig. 9
The induction hob must be connected to the mains by a suitably qualified person.
Before connecting the hob to the mains, check that:
1. Your home wiring system is suitable for the power consumption of the cooking hob.
2. The mains voltage matches the voltage stated on the rating label of the appliance.
3. The power cable sections can withstand the load specified on the product rating label.
-
To connect the induction hob to the mains, do not use adapters, reducers or branching
devices, as they may cause overheating or fire.
-
The power cord should not be in contact with any hot parts and must be positioned so as
to avoid its temperature exceeding 75 °C.
Warning
-
Check with an electrician whether your home wiring system is suitable without modifying
it.
Any modifications should only be carried out by a qualified electrician.
It can be connected directly to the mains by means of a single-phase/three-phase electrical
connection, as shown in fig. 9.
Legend Fig. 9:
Neutral (N2) blue wire
1.
Neutral (N1) grey wire
2.
Phase 2 (L2) brown wire
3.
Phase 1 (L1) black wire
4.
5.
Yellow/green earth wire
-
If the cord of the induction hob is damaged, it must be replaced by the manufacturer, the
supplier, or similarly qualified personnel to avoid a hazard.
-
If the appliance is connected directly to the mains, a single-pole residual current circuit
breaker with a minimum contact separation of 3 mm must be installed.
-
The person in charge of the installation must ensure that a correct electrical connection
has been made and that it complies with safety regulations.
ENGLISH
63
BOLERO SQUAD I 3250

Publicidad

loading

Este manual también es adecuado para:

02764