5. Pull the trigger of the spray gun in order to pump the
remaining coating material from the hopper, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
The container must be earthed in case of coating
materials which contain solvents (e.g. by using a
metal container).
Caution! Do not pump or spray in container with
small opening (bunghole)!
See safety regulations.
6. Fill up hopper with suitable cleaning agent.
7. Set pressure relief valve to
8. Pump suitable cleaning agent in the circuit for several
minutes.
9. Set pressure relief valve to
10. Pump the remaining cleaning agent from the hopper,
high-pressure hose and the spray gun into an open
container.
For long-term, cold weather storage, or any
i
freezing temperature exposure pump mineral
spirits through the entire system.
For short-term storage not exposed to freezing
temperatures when using latex paint, pump
water mixed with Titan Liquid Shield through
the entire system (see Accessories section of this
manual for part number and product label for
dilution instructions).
11. Set pressure relief valve to
12. Switch the pump OFF using the ON/OFF switch (Pos. 0).
(circulation).
(spray).
(circulation).
8.1
CLEANING THE UNIT FROM THE OUTSIDE
Danger of short-circuits caused by water
ingression!
Never spray down the unit with high-pressure or
high-pressure steam cleaners.
Do not put the high-pressure hose into solvents.
Use only a wet cloth to wipe down the outside of
the hose.
Attention
Wipe down unit externally with a cloth which has been
immersed in a suitable cleaning agent.
8.2
SUCTION FILTER
Clean filters always ensure maximum volume,
i
constant spray pressure and problem-free
functioning of the unit.
1
SUCTION SYSTEM
UNIT WITH SUCTION SYSTEM
1. Unscrew the filter (Item 1) from the suction tube.
2. Clean or replace the filter.
Carry out cleaning with a hard brush and a corresponding
cleaning agent.
UNIT WITH OPTIONAL HOPPER
1. Remove screws with a screwdriver (Item 2).
2. Lift and remove filter disk (1) with a screwdriver
3. Clean or replace the filter disk.
Carry out cleaning with a hard brush and a appropriate
cleaning agent.
CLEANING THE UNIT
2
1
HOPPER
15