Descargar Imprimir esta página

Titan ELITE 2000 Instrucciones De Uso página 17

Airless equipo de alta presión para pulverizar

Publicidad

Idiomas disponibles

Idiomas disponibles

ELITE 2000
9
SERVICING
9.1
GENERAL SERVICING
We strongly recommend having an annual check
i
carried out by technicians for safety reasons.
Please observe all the applicable national
regulations.
MINIMUM CHECK BEFORE EVERY STARTUP:
1. Check the high-pressure hose, spray gun with rotary joint,
power supply cable with plug for damage.
CHECK AT PERIODICAL INTERVALS:
1. Check inlet and outlet valve according wear. Clean it and
replace worn out parts.
2. Check all filter inserts (spray gun, suction system) clean it
and replace if necessary.
9.2
HIGH-PRESSURE HOSE
Inspect the high-pressure hose visually for any notches or
bulges, in particular at the transition in the fittings. It must be
possible to turn the union nuts freely. A conductivity of less
than
1 MΩ must exist across the entire length.
Have all the electric tests carried by Titan Service.
The risk of damage rises with the age of the high-
pressure hose.
Attention
Titan recommends replacing high-pressure
hoses after 6 years.
SERVICING
17

Publicidad

loading