Cable calibration
Cable calibration
Automatic
Manual
Automatic calibration (recommended)
Cable calibration
Be sure that the metal portions of the jaws to which the cables are attached are in proper
contact with each other.
OK
Manual calibration (not recommended)
Cable calibration
11.5
m
24
Translation of the original
instructions
1
Connect the USB stick to the Gysflash
2
Enter the «Export DATA» submenu.
3
Confirm that the charging data has been saved.
The Gysflash will then copy the charging data to the USB stick in the form of a
4
«.CSV» file.
Cables can be calibrated either automatically (recommended) or manually.
This procedure is used to calibrate the charging cables of the unit, so the Gysflash can
effectively compensate for any voltage drop caused by the cables. We strongly recommend
that you carry out this procedure every time you replace your cables, or if they are getting
worn.
To calibrate, simply short-circuit the charging clamps and then confirm.
The device then automatically calculates the cable resistance.
NOK
The cable resistance can be set manually.
Warning: this value must include the internal resistance of the Gysflash.
GYSFLASH 107.24 CNT FV
NOK