Descargar Imprimir esta página

V2 HYPERFOR4000-I Manual Del Usuario página 62

Motor electromecanico irreversibles 230v trifasico con inverter para puertas correderas hasta 4000 kg de peso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 100
PARAMETER
VALUE
FT.TE
0.1"-2.0"
NO
COS1
NO
APCH
AP
COS2
NO
APCH
CH
CO.TE
NO
RESI
FOTO
CH.OS
MAN
AUTO
I.ADI
NO
SI
RICH
NO
SI
T.ADD
0.5"-1'
NO
FINE
NO
SI
- 60 - ENGLISH
SUBMENU
DESCRIPTION
Photocell test enable
Function disabled
Safety ribbon 1 mode
No function
Enabled opening and closing
Enabled opening
Safety ribbon 2 mode
No function
Enabled closing and opening
Enabled closing
Ribbon type and test
Mechanic - no test
Resistive
Optical with test
Closure after obstacle
Manual
Automatic (if activated through CH.AU
parameter)
ADI device enable
ADI interface disabled
ADI interface enabled
Reclosing at startup
Function disabled
When the power supply is activated the unit
set for closing: the first START command starts
the motor closing. If the automatic closing is
activated (CH.AU), the count of pause time
starts and closing is activated
Extra travel
If in some cases the gate does not reach the
position needed to activate the limit switch,
you can set an additional time by configuring
the parameter
not activated the gate continues its movement
up to the end of the set time
The gate ends its travel even if the limit
switches have not been activated
Exit the programming menu
Do not exit the programming menu
Exits the programming menu by storing the
parameters set
: if the limit switches is
T.ADD
DEFAULT
CHAPTER
MEMO
11.1
NO
12.2
NO
12.2
NO
12.2
NO
12
MAN
21
NO
SI
1.0"
NO

Publicidad