Furman PS-8RE III Manual De Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
P S - 8 R E I I I - P O W E R C O N D I T I O N E R / S E q U E N C E R
PIN 4 GND (Remote Interface Common)
The GND (ground) terminal pin serves a ground reference
point for all other pins on the Remote Interface. GND can
also be fed back into the REM pin (Pin #3) to activate the
sequence when the PS-8RE III has been configured for
GND ON mode. Please note that the GND terminal on
the Remote Interface is not the same as chassis ground.
DIP Switch
A rear panel three position DIP switch is used to set the
sequence mode (+12V ON, +12V OFF, GND ON, Mom/
Maint) which defines how the PS-8RE III will react to
the signal presented on its REM input. The table below
summarizes the behavior which is described in further
detail below. Note that DIP switch position 2 overrides
the setting of DIP switch 1, and DIP switch 3 overrides
switches 1 and 2.
DIP 2
DIP 1
1 2 3
GND ON
12V ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
DIP Switch position #1 (Factory default is OFF)
DIP Switch position 1 defines how the PS-8RE III will
behave when +12VDC is applied to the REM pin on the
Remote interface. If this switch is in the ON position, the
PS-8RE III will sequence ON when +12V is applied to the
REM input. If this switch is in the OFF position (+12V OFF)
the PS-8RE III will sequence OFF when +12V is applied
to the REM input. DIP switches 2 and 3 must be in the
OFF position (Maintained mode)
Note: The front panel SEQUENCE ON/OFF switch acts as an override. The SEQUENCE switch must be
MODE
DIP 3
in the ON position for any of the sequenced outlets to be activated.
MOM/MNT
Sequences the PS-8RE III ON when REM = Open Circuit
+12V OFF
OFF
Sequences the PS-8RE III OFF when REM = 12VDC
Sequences the PS-8RE III ON when REM = 12VDC
+12V ON
OFF
Sequences the PS-8RE III OFF when REM = Open Circuit
GND ON
OFF
Sequences the PS-8RE III ON when REM is connected to GND terminal.
Sequences the PS-8RE III OFF when REM = Open Circuit
GND ON
OFF
Momentary
ON
Momentary
ON
Sequences the PS-8RE III from ON to OFF or OFF to ON each time +12V is applied to the REM input.
ON
Momentary
ON
Momentary
.
12V ON
1
12V OFF
12V STAT REM GND
REMOTE PORT
12V ON
1
1 2 3
12V OFF
DIP Switch position #2 (Factory default is OFF)
DIP Switch position 2 defines how the PS-8RE III will
behave when GND is applied to the REM pin on the
Remote interface. If this switch is in the ON position, the
PS-8RE III will sequence ON when GND is applied to the
REM input. If this switch is in the OFF position the PS-8RE
III will follow the behavior defined by DIP Switch #1. DIP
switch 3 must be in the OFF position (Maintained mode).
6
1 2 3
MOM
3
MNT
12V 0.5A
GND
2
ON
MOM
3
MNT
FACTORY DEFAULT SETTING
GND
2
ON

Publicidad

Tabla de contenido
loading

Tabla de contenido