Choosing Nozzle Type; Influence Of Climatic Conditions - Jacto PJ-16 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: For the volume in liters per bushel (L / alk), simply multiply
the value obtained in liters per hectare (L / ha) by 2.42.
WARNING!
Wear a protective clothes to do the mainte-
nance and parts replacement.

4.3. Choosing nozzle type

Seven main nozzle designs are used on knapsack sprayers. Each
nozzle design is available in a range of sizes to optimize the use
of product to be applied. The nozzle choice will be based on the
agrochemical type to be used and the droplet size recommend-
ed (table):
NOTE: This sprayer is packaged with Blue Adjustable Cone noz-
zle fitted in the lance. Other nozzles mentioned in this manual
are optional, so they do not accompany this sprayer.
IDENTIFICATION
NOZZLE
FILTER (Mesh)
TYPE
(Part no. - Description)
(1197535) JEF 110015
80 (Zinc yellow)
GREEN
(1197536) JEF 11002
50(Gentian blue)
YELLOW
(1197537) JEF11003
50(Gentian blue)
(1197475) JSF 110015
80 (Zinc yellow)
GREEN
(1197476) JSF 11002
50(Gentian blue)
YELLOW
(1197477) JSF11003
50(Gentian blue)
(1197565) JHC 8002
50(Gentian blue)
YELLOW
(1198892) JHC 8004
50(Gentian blue)
(1198893) JHC 8005
50(Gentian blue)
BROWN
(1197486) JDF 04
50(Gentian blue)
(1197487) JDF 05
50(Gentian blue)
BROWN
(1197488) JDF 06
50(Gentian blue)
(1197497) JAI 120015
80 (Zinc yellow)
(1197499) JAI 12002
80 (Zinc yellow)
YELLOW
(1197501) JAI 12003
50(Gentian blue)
8/53
PRESSURE
APPLICATION
(psi)
30
Herbicides
30
30
BLUE
30
Herbicides
30
30
BLUE
45
Fungicide,
insecticide
45
RED
and
foliar
fertilizers
45
15
RED
Herbicides
and
15
foliar
fertilizers
15
GREY
20
GREEN
Herbicides
20
20
BLUE
Nozzle
Code
1197571
217174
1197537
1197477
325787
1197486
1197486
FLOW RATE
(l/min)
Recommended
0.49
0.65
Prevent the flow rate to be higher than 10% of the nozzle nom-
inal flow rate.
0.98
It is recommended to use the pressure and flow rate regulating
0.49
valve (ECOVALVE) in order to achieve a more accurate spraying
0.65
method.
0.58
0.80
1.60
Code:1197164
2.00
0.92
1.15
Code:1197159
1.39
0.42
Code:1197163
0.57
0.85
Code:1197162

4.4. Influence of climatic conditions

During application, some factors may determine the interrup-
tion of the spraying. Wind currents, for example, can drag drops
to a greater or lesser distance in terms of its size or weight. The
temperature and especially the relative humidity contribute to
the rapid evaporation of the droplets.
The ideal conditions for spraying are:
• Relative humidity: minimum 50%;
• Wind speed: 3-10 km / h;
Herbi-
cide
Name
Picture
JHC
JD-12
JEF
JSF
J ADJ
JDF
JAI
Acceptable
Fungi-
Insec-
cide
ticide
Not recommended
0.8 Bar (0.8 kgf/cm²)
1.0 Bar (1.0 kgf/cm²)
1.2 Bar (1.2 kgf/cm²)
1.3 Bar (1.3 kgf/cm²)
1.5 Bar (1.5 kgf/cm²)
1.7 Bar (1.7 kgf/cm²)
1.8 Bar (1.8 kgf/cm²)
2.0 Bar (2.0 kgf/cm²)
2.3 Bar (2.3 kgf/cm²)
2.8 Bar (2.8 kgf/cm²)
3.0 Bar (3.0 kgf/cm²)
3.2 Bar (3.2 kgf/cm²)

Publicidad

Tabla de contenido
loading

Tabla de contenido