SOFTWARE

In case of exchange of the control unit, software must
be reloaded, using an SD card.
Latest software can be downloaded under Product
software at www.migatronic.com/login. Save the
software on an SD card containing the folders and one
or more of the files shown below.
To order SD card, use item no. 12646000.
Software reading
 Insert the SD-card in the slide in the right side of
the machine.
 Turn on the machine.
 The display flashes shortly with three lines.
 Wait until the set current is displayed.
 Turn off the machine and remove the SD card.
 The machine is now ready for use.
All machine user settings are deleted
when new software has been inserted.
Therefore, always remove the SD-card from
the machine after the software update.
Thereby, continuous software update is
avoid each time the machine is turned on.

TECHNICAL DATA

Power source:
Mains voltage (50Hz-60Hz)
Fuse
Mains current, effective
Mains current, max.
Power, (100%)
Power, max
Open circuit power
Efficiency
Power factor
Current range
Duty cycle 100%
at 20°C
Duty cycle
60%
at 20°C
Duty cycle
40%
at 20°C
Duty cycle 100%
at 40°C
Duty cycle
60%
at 40°C
Duty cycle
25%
at 40°C
Open circuit voltage
1
Sphere of application
2
Protection class
Norm
Dimensions (LxWxH)
Weight
S
1
This machine meets the demand made for machines which are to
operate in areas with increased hazard of electric chocks
2
Equipment marked IP23 is designed for indoor and outdoor applications
15
RALLY MIG 161i
1x230V
16A
13A
22.9A
2.4kVA
4.4kVA
30W
0.8
0.99
20-160A
135A
145A
160A
100A
115A
160A
75V
S
IP 23
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
45x23x37 cm
13 kg