Blade Block Guard; Basic Working Techniques; Operation - Husqvarna Soff-Cut 150 E Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Blade block guard

The blade block guard gives protection from the rotating
blade and keeps dust away from the operator.
Introduction
WARNING: Read and understand the safety
chapter before you use the product.

Basic working techniques

Contraction joints and joint spacing
As concrete hydrates or cures and begins to set, it
develops internal stresses which may cause random
cracks.
Random cracks cast doubt on the quality and
workmanship of the concrete. Contraction joints are cut
in concrete to relieve these stresses before they seek
their own relief in the form of random crack.
The Soff-Cut Ultra Early Entry system controls random
cracking through the early timing of a saw cut at
predetermined locations to create weakened planes in
the concrete that subsequently crack at the bottom of
the cut to relieve stress.
Sawed contraction joints must be a minimum of ⅛ of the
concrete depth and a minimum of 25 mm (1ʺ) deep.
Saw contraction joints when the concrete holds the
weight of the product and the operator. Make sure that
the product does not make marks on or cause damage
to the concrete.
There are many possibilities for joint layout. Joint layout
should be provided, the saw contractor should submit a
detailed joint layout for approval prior to cutting.
There are many conditions that have an effect on joint
spacing.
Concrete thickness.
Type, amount and location of reinforcement.
12

Operation

Shrinkage potential of concrete-cement (type,
quantity), aggregate (size, quantity, quality), water to
cement ratio, admixtures, concrete temperature.
Base friction.
Slab restraints.
Layout of foundations, racks, pits, equipment pad,
trenches, etc.
Environmental factors - temperature, wind, humidity.
Methods and quality of concrete curing.
Generally, contraction joint patterns should divide slabs
into approximate square panels per the recommended
spacing shown in the table.
Concrete thickness, mm
(in.)
90 (3.5)
100, 114 (4, 4.5)
125, 140 (5, 5.5)
150 (6) or greater
At all intersecting cross cuts, install Husqvarna joint
protectors at each joint to prevent joint damage. Install
an additional joint protector where the right wheel will
cross the joint to prevent concrete damage.
Maximizing the Soff-Cut system
"The timing of concrete operations - especially finishing
and jointing - is critical... Failure to address this issue
can contribute to undesirable characteristics in the
wearing surface as cracking..." (Extract from the
foreword of the American Concrete Institute (ACI) 302.1
R-96.)
The Soff-Cut Ultra Early Entry system has revolutionized
the method used to control random cracking.
Maximum spacing, m (ft.)
2.4 (8)
3.0 (10)
3.6 (12)
4.5 (15)
1038 - 002 - 17.10.2019

Publicidad

Tabla de contenido
loading

Tabla de contenido