POWR
EXPLODED DIAGRAM
5 × 14 mm
4.9 N • m (0.49 kgf • m, 3.5 ft • Ib)
LT
242
5
14 N • m (1.4 kgf • m, 10 ft • Ib)
6 × 35 mm
LT
242
3
6 × 14 mm
14 N • m (1.4 kgf • m, 10 ft • Ib)
REMOVAL AND INSTALLATION CHART
Step
Procedure/Part name
STATOR COIL AND PICKUP
COIL REMOVAL
1
Plastic tie
2
Bolt/washer
3
Bolt
4
Cable holder
5
Bolt
6
Pickup coil
7
Bolt
GENERATOR AND STARTER MOTOR
2
6
5 × 14 mm
6
LT
242
10
5
9
LT
242
5 × 14 mm
4
2
1
8
2
7
5 × 14 mm
5 × 14 mm
4.9 N • m (0.49 kgf • m, 3.5 ft • Ib)
Q'ty
Follow the left "Step" for removal.
1
Not reusable
NOTE:
3/3
These washers hold the pickup coil leads.
2
Be sure not to pinch the leads between the
1
projections and the washers when installing
6
the bolts.
3
1
5-39
6
5
LT
242
Service points
E