ENGLISH
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
NOTE
With reference to Delegated Regulation (EU) No. 811/2013, the data in the table can be used for completing the product card and the labelling for
ambient heating appliances, for mixed heating appliances, for assemblies of appliances for ambient heating, and for temperature control devices
and solar devices:
ADDED DEVICE
EXTERNAL PROBE
CONTROL PANEL (*)
EXTERNAL PROBE + CONTROL PANEL (*)
(*) Set as room temperature controller
20
Symbol
Mynute Boiler Green
25 B.S.I. E
-
A
-
A
Pnominal
25
ηs
92
P4
24.5
P1
8.0
η4
88.8
η1
96.4
elmax
40.0
elmin
13.7
PSB
2.4
Pstby
58.0
Pign
-
QHE
48
LWA
53
NOx
35
XL
ηwh
83
Qelec
0.183
Qfuel
23.579
AEC
40
AFC
18
Class
II
V
VI
Mynute Boiler Green
35 B.S.I. E
A
A
34
92
33.7
11.2
87.9
97.3
68.0
22.1
2.4
42.0
-
58
52
24
mg/kWh
XL
81
0.345
23.814
76
18
Bonus
2%
3%
4%
Unit
-
-
kW
%
kW
kW
%
%
W
W
W
W
W
GJ
dB
%
kWh
kWh
kWh
GJ