1 -

WARNINGS AND SAFETY

b
Our boilers are built in our plants and checked down to the
smallest detail in order to protect users and fitters from injury.
After working on the product, qualified personnel must check
the electrical wiring, in particular the stripped part of conductors,
which must not stick out from the terminal board, avoiding
possible contact with live parts of such conductor.
b
This instruction manual, together with the user manual, are
integral parts of the product: make sure that they are always
kept with the appliance, even if it is transferred to another owner
or user, or moved to another heating system. In case of loss
or damage, please contact your local Technical Assistance
Service for a new copy.
b
The boiler must only be installed and serviced by qualified
personnel, in accordance with the regulations in force.
b
Boiler maintenance must be carried out at least once a year.
This should be booked in advance with the Technical Assistance
Service.
b
The installer must instruct the user about the operation of the
appliance and essential safety requirements.
b
This appliance should not be operated by children younger
than 8 years, people with reduced physical, sensory or mental
capacities, or inexperienced people who are not familiar with the
product, unless they are given close supervision or instructions
on how to use it safely and are made aware by a responsible
person of the dangers its use might entail. Children must not
play with the appliance. It is the user's responsibility to clean
and maintain the appliance. Children should never clean or
maintain it unless they are given supervision.
b
This boiler must only be used for the application it was designed
for. The manufacturer declines all contractual and non-
contractual liability for injury to persons or animals or damage
to property deriving from errors made during installation,
adjustment and maintenance and from improper use.
b
After removing the packaging, make sure the content is in good
condition and complete. Otherwise, contact the dealer from
whom you purchased the appliance.
b
The appliance's discharge manifold must be connected to a
suitable venting system. The manufacturer of the appliance is
not liable for any damage/flooding resulting from the failure of
the channel system.
b
Dispose of all the packaging materials in the appropriate
containers c/o specific collection centres.
b
Dispose of waste taking care not to harm human health and
without employing procedures or methods which may damage
the environment.
b
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut
off and the Technical Assistance Service must be contacted
immediately
- regularly check that the operating pressure of the hydraulic
system is greater than 1 bar. If necessary, restore the pressure
as explained in the "System filling" section
- if the boiler has not been used for a long time, it is recommended
that the Technical Assistance Service performs, at least, the
following operations:
- turn the main switch of the appliance and the main switch
of the system to "off"
- close the fuel and water taps of the heating system
- drain the heating circuit to prevent freezing.
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
4
For safety, always remember that:
a
It is dangerous to operate electrical devices or appliances
(such as switches, home appliances, etc.) if you smell gas or
combustion fumes. In the event of gas leaks, ventilate the room
opening doors and windows; close the gas general tap; request
prompt action by Technical Assistance Service professionally
qualified personnel.
a
Do not touch the boiler while barefoot, or if parts of your body
are wet or damp.
a
Set the function selector switch to OFF/RESET to bring up "- -"
on the display, then disconnect the boiler from the main power
supply by turning off the main system switch before carrying out
any cleaning operations.
a
Do not modify safety and adjustment devices without the
manufacturer's permission and relative instructions.
a
Do not pull, disconnect or twist the electric cables coming out
of the boiler, even when it is disconnected from the main power
supply.
a
Only for the user: Do not access the inside of the boiler. Any
work on the boiler should be carried out by the Technical
Assistance Centre or by professionally qualified personnel.
a
Avoid covering or reducing the size of the ventilation openings
in the installation room.
a
Do not leave inflammable containers and substances in the
installation room.
a
Keep packaging materials out of the reach of children.
a
It is forbidden to obstruct the condensate drainage point.
2 -
DESCRIPTION
MySMART C.S.I. is a wall-mounted type C condensation boiler for
heating and the production of domestic hot water. Depending on
the fume discharge accessory used, it is classified in categories
B23P;B53P; C13,C13x; C33,C33x; C43,C43x; C53,C53x; C63,C63x;
C83,C83x; C93,C93x.
In configuration B23P (when installed indoors), the appliance cannot
be installed in bedrooms, bathrooms, showers or where there are
open fireplaces without a proper air flow. The room where the boiler
is installed must have proper ventilation. Detailed regulations for the
installation of the flue, gas piping and ventilation ducting are given in
standards UNI 7129-7131.
In configuration C, the appliance can be installed in any type of room
and there are no limitations due to ventilation conditions or room
volume.
3 -
INSTALLATION
3.1

Installation regulations

Installation must be carried out by qualified personnel in compliance
with local regulations.
b
During boiler installation, the use of protective clothing is
recommended, in order to avoid personal injury.
POSITION
MySMART C.S.I. is a wall-mounted boiler for heating and for the
production of hot water. There are two categories, depending on the
type of installation:
1.
B23P-B53P type boiler - forced open installation, with flue
gas discharge pipe and pick-up of combustion air from the
installation area. If the boiler is not installed outdoors, air intake
in the installation area is compulsory.
2.
C13, C13x; C33, C33x; C43, C43x; C53, C53x; C63, C63x; C83,
C83x, C93, C93x: appliance with airtight chamber, with flue gas
discharge pipe and pick-up of combustion air from outside.
It does not require an air intake point in the installation area.
This type MUST be installed using concentric pipes, or other
types of discharge designed for condensation boilers with an
airtight chamber.

Publicidad