Fix the box to the wall, using the screw supplied.
Attach the bracket, then tighten the screw.
Loosen the nut of the cable grommet, then insert the probe connection
cable and connect it to the electric clamp.
To make the electrical connection between the external probe and
the boiler, refer to the "Electrical wiring" chapter.
b
Remember to close the cable grommet well, to prevent any air
humidity getting in through the opening.
Put the card back in its seat.
Close the plastic upper protective cover by turning it clockwise.
Tighten the cable grommet very well.
3.6
Installation of the remote control panel
To correctly check the ambient temperature, the control panel should
be installed in a reference position in the home.
For a correct installation, keep in mind that the panel:
ƒ it should be installed on a wall, preferably not a perimeter one, that
has no hot or cold pipes running through it
ƒ It should be fixed about 1.5 m from the ground
ƒ It should not be installed near doors or windows, cooking
equipment, radiators, fan coils or generally in conditions that
might alter the measured temperatures.
SI
In order to fix the panel to the wall, proceed as follows:
ƒ separate the control panel from the base
ƒ use the base as a template for marking the fixing points on the
wall
ƒ drill holes in the wall (ø 6 mm holes)
ƒ fix the base to the wall using the screws supplied
YES
ƒ insert 2 type AA batteries
ƒ attach the top part of the panel to the base
6
NO
NO
ƒ connect the red wires of the USB cable of the WiFi Box to the OT
clamp of the boiler - see wiring diagram
connect the plug of the USB cable to the OUTPUTS/BOILER
ƒ
output of the WiFi Box.
USB
Put the WiFi Box onto the hood of the boiler using the magnet on the
ƒ
back.
ƒ Position the WiFi Box in a place where the WiFi signal is not weak
(recommended above 30%).
ƒ Power up the WiFi Box using the relative cable and power supply
provided as standard.
USB
TA = Black
OT = Red