Advanced Functions Programming (D1= "A")
D1 D2
Parameter
A
0
Flashing light
1
Garage light time
2
Nominal torque/force
3
Regulation of slowdown
torque/force and speed
5
Reverse after closing
(prevents the operator
from seizing up on the
stopper)
6
Maximum trapping
torque/force (level of
increase relative to
nominal)
The digit D3 allows the
level to be adjusted
during opening
The digit D4 allows the
level to be adjusted
during closing
7
Cross over photocell
(opening or closing)
during stand-by (in
automatic mode only)
8
Effect of ST1-ST2
pushbuttons during
stand-by time (in
automatic mode only)
9
Opening mode
A
Lapse between leaves in
opening and closing
b
U s i n g t h e E P S 1 c a r d
connector
For parameters Ab02 and
Ab03, use the EPS1 card
and bridge the network
input cable connectors
instead of connecting
them to the network (see
d i a g r a m
c o n n e c t i o n s "
page 71).
C
Hydraulic pressure
maintenance
d
Ram
E
Special functions
Default
D3
D4
option
0
1, 2
0..5.
0...9
0
1...9
0
1...9
0
0...5
0...9
0...9
0
0...2
0
0...2
0
1...3
0...9
0...9
0
0...3
" B r a k e
o n
0
0...6
0
0,1
0
0...2
STARTING UP AND PROGRAMMING
Options or values
01
01: output with voltage, without pre-warning
02: output with voltage, with pre-warning
03
03 = 3 sec.;
59 = 59 sec.;
2.5 = 2 min. 50 sec.,
etc, maximum 4 minutes
09
01: minimum,..., 09: maximum
09
01: minimum,..., 09: maximum
00
00: no reverse,
...,
05: maximum reverse
00
00: disabled in opening and closing;
01: disabled in opening and level 1 in closing;
10: level 1 in opening and disabled in closing;
...;
65: level 6 in opening and level 5 in closing;
...;
99: level 9 in opening and closing
02
00: does not affect stand-by time
01: immediate close when the photocells are
released
02: restarts stand-by time
02
00: have no effect during stand-by
01: produce closing after 3 seconds
02: restart stand-by time
02
01: collective opening
02: step-by-step alternative stop
03: automatic alternative stop (if
F200 is selected, A903 becomes A902)
22
00: no lapse in opening or closing,
(only apply in gates without overlap);
XY: X lapse in opening
(X=1: 1 second, ... , X=9: 9 seconds)
Y lapse in closing
(Y=1: 1 second, ... , Y=9: 9 seconds)
00
00: use for standard traffic light;
01: use for brakes
02: NC contact with gate open (L1-COM) and
gate closed (L2-COM)
03: impulse 1 second Open (L1-COM) when
starting opening and Close (L2-COM) when
starting closing. Allows another board to be
activated
00
00: no maintaining pressure;
01: every 0.5 hours; 02: every 1 hour;
03: every 2 hours;
05: every 12 hours;
00
00: no ram; 01: with ram
00
00: no special function;
01: opening photocell C4 programmed for
pedestrian crossing;
02: industrial
04: every 6 hours;
06: every 24 hours
Control board VIVO-M203(M)