PNEUMATIC CONNECTION

To connect the pump to the pneumatic circuit, you must:
WARNING
WARNING
1. Remove the adhesive sticker from the air connection.
2. Install an on-off valve, a three-way valve and a check valve on the pneumatic cir-
cuit connection on board the pump according to the layout shown in figure 1.
REMARK
ONLY FILTER
pneumatic supply to the Piusi MA and Piusi MP
pumps must be made using FILTERED, DRIED, NON
LUBRICATED OIL FREE AIR at a pressure of not less
than 2 bars and not more than 7 bars.
do not remove RESET for any reason and/or do not
connect the air supply to the RESET channel.
to measure the actual air pressure, install a pressure
gauge on the air connection of the pump and check
the value while the pump is running.
NO OIL
FORMATO 30X44 mm
NERO
ROSSO p.186
55/208
EN