COMMISSIONING
The user must always use materials that are compatible with the pumped liquid
according to the pump's design conditions.
WARNING
To commission the pump, proceed as follows:
1. Make sure that the product delivery and intake hoses are correctly connected -
check the signs on the pump:
"IN" = INTAKE (down) and
"OUT" = DELIVERY (up)
2. Check that the pump's pneumatic circuit valves are correctly installed (on-off ball
valve, three-way valve and check valve).
3. Open the fluid intake and delivery valves.