Technical data
FlexFilter EX
Max operating air flow
Max vacuum
Process air (dry) temperature
Operating temperature
Main filter area
Main Filter material
Control filter area
Control Filter material
Control Filter pressure switch preset
Compressed air quality:
Required air pressure
Max air consumption (intermittent)
Connection,
Control voltage
Internal fuse/s (fast acting)
Control signal fuse (max)
Dimensions
Dimension inlet
Dimension outlet
Weight dust separator (approx)
Weight deflector
Area relief panel
Relief panel burst pressure
Material description
Material recycling
FlexFilter EX
Single
1600 m³/h (942 cfm)
-50 kPa (-7 .25 PSI)
0 - 60°C (32 - 102°F)
-10 - +40°C (14 - 104°F)
1x12 m² (1x129 sqft)
Conductive (<10ˆ8 Ω) polyester
1x12 m² (1x129 sqft)
4 kPa (0,58 PSI)
Clean dry, ISO 8573-1 class 5
6 - 10 bar (87 - 145 PSI)
700 N-Litres/min (25 cfm)
Hose nipple 12 mm (1/2 in)
24 V DC ± 10%
See pictures no . 3 / a-f
Flanged Ø 150 mm (5 .9 in)
1x Ø 203,2 mm (8 in)
255 kg (562 lb)
1x11 kg (1x24,25 lb)
1x0,096 m² (1x1,03 sqft)
0,1 bar (1.45 PSI)
Powder coated steel
Approx . 94 weight-%
Twin
3200 m³/h (1884 cfm)
2x12 m² (2x129 sqft)
2x12 m² (2x129 sqft)
Polyester
1400 N-Litres/min (50 cfm)
250 mA (5x20)
5 A
Flanged Ø 200 mm (7 .87 in)
2x Ø 203,2 mm (8 in)
485 kg (1069 lb)
2x11 kg (2x24,25 lb)
2x0,096 m² (2x1,03 sqft)
EN
23