Beninca CP.B24 Manual De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
MENU
The automatic closure is enabled or disabled.
TCA
Off: disabled automatic closure.
On: enabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse
IBL
of the transmitter has no effect in the opening phase.
Off: disabled multi-flat function.
The PP and PED controls during the TCA are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The rapid closure is enabled or disabled.
On: enabled rapid closure. With open gate or gate in the opening phase, the
activation of the photocell causes the automatic closure of the gate 3 sec after
SCL
its activation.
This function is enabled only with TCA:ON
Off: rapid closure disabled.
The operating mode of the "P.P." (Step-by Step) button and of the transmitter
is selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 sec be-
PRE
fore the motor starts.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
On: Service Man operation.
HTR
The OPEN/CLOSE push buttons should be kept pressed for the entire operating
time.
Off: Automatic operation.
Raking is enabled or disabled.
SLD
On: Braking enabled.
Off: Braking disabled.
The forewarning flashing light is enabled or disabled during the TCA time.
LTCA
On: Flashing light enabled.
Off: Flashing light disabled.
The OPEN input mode is selected.
On: OPEN input, with CLOCK function.
CLOC
To be used for connection to timer for timed opening/closing. (CLOSED contact:
open gate. OPEN contact: normal operation).
Off: OPEN input, with OPEN function
The Encoder is enabled or disabled.
ENC
On: Encoder enabled.
Off: Encoder disabled.
The programmable code transmitters are enables or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code transmitters and programmable code
transmitters (self-learning and DIPswitch) .
Check of OPEN and CLOSE relays is enabled or.
On: Check activated: if one of the 2 relays is faulty, the motor does not start and
TREL
the error message "ERR2" is displayed.
Off: no check to relays is carried out.
Reduced speed starting is enabled or disabled.
On: Starting is performed at reduced speed for 2 seconds and then movement
SOFT
is restored to normal speed.
Off: Reduced speed start is disabled.
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
FUNCTION
MEMO
DEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
13

Publicidad

Tabla de contenido
loading

Tabla de contenido