ELEC
L
Br
O
IGNITION SYSTEM
10
1, 2
B
IGNITION SYSTEM PEAK VOLTAGE
w
When checking the CDI unit do not touch
any of the connections of the digital tester
lead wires.
1. Measure:
9 CDI unit output peak voltage
Below specification → Replace the
ignition coil or check the CDI unit.
6 A model
Output peak voltage
Cranking
r/min
Opened Closed
V
120
10 A model
Output peak voltage
Cranking
r/min
Opened Closed
V
120
2. Measure:
9 Charge coil output peak voltage
Below specification → Replace the
charge coil.
6 A model
Output peak voltage
Cranking
r/min
Opened Closed
V
130
10 A model
Output peak voltage
Cranking
r/min
Opened Closed
V
130
8-13
O-B
1,500
3,500
115
160
160
O-B
1,500
3,500
120
160
160
Br-L
1,500
3,500
135
180
180
Br-L
1,500
3,500
135
180
180
E