Rothenberger ROWELD P 160 B Instrucciones De Uso página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
Heating is displayed on the hand grip by the yellow diode. Horizontal bars also appear on the
temperature indicator. The yellow diode goes out shortly before reaching the set nominal tem-
perature (tolerance +/-3° C / 5.4° F) and the green one lights up. The heating element is usable
after a further 10 minutes. Note: upon first reaching the nominal temperature the set value can
be exceeded for short time.
Check the temperature using an external temperature measuring instrument. If there are de-
viations it means that the heating element must be re-calibrated: press the "+" and "-" button
simultaneously and then set the difference using the "+" or "-" button.
If "Er1" appears this means the electronics are defective. For "Er2" the resistance thermometer
is either defective or not connected. Send the device to an authorised ROTHENBERGER speci-
alist workshop.
Risk of serious injury! The heating plate can reach temperatures of over 290° C /
554° F! We highly recommend storing the heating plate in the designated carrying
frame immediately after use!
For P355/12B:
Turn on the main switch of the control box. The switch lights up green and the actual tem-
perature of the hotplate is shown on the display. Use the – and + keys to set the desired
temperature between 160° C and 270° C / 320° F and 518° F.
When the set temperature is reached, the display jumps from "set" to "actual", and the "heat"
display blinks. The heating element is ready to use after another 10 minutes.
Check the temperature with a temperature measurement device.
The temperature regulator is optimally set at the factory. If the actual surface temperature on the
heating element does not reflect the temperature shown, an offset can be performed. For this,
set the rocker switch to 0, press the – and + keys, and turn the rocker switch on. The display
shows "OFF", "SET" and then the set offset value. Use the – and + keys to set the offset appro-
priately, and save it by pressing – and +. Then the current value is shown again.
For P500-630/18-24B Plus:
Switch on master switch in the control box / heating plate (the switch lights green when
power supply properly connected). Set required temperature (cf. temperature controller).
The display generally indicates the actual temperature value. In accordance with national ordi-
nances and guidelines, e. g. DVS, the heating plate is ready after maintaining the setpoint tem-
perature for at least 10 minutes.
Check the temperature with a temperature measurement device.
Risk of serious injury! The heating plate can reach temperatures of over 300° C /
572° F! We highly recommend storing the heating plate in the designated carrying
frame immediately after use!
The welding machine is equipped with a Type 400 digital temperature controller.
The digital temperature controller has been ideally configured and set before leaving our factory.
To set temperature simply press the
tor can now adjust the setpoint temperature between 0-300° C / 32-572° F with the arrow keys.
If no keys are pressed, the display indicates the actual temperature, the controller automatically
sets the new temperature parameter. As long as the actual temperature is lower than the set-
point temperature, the red arrow flashes (low). If the actual value is larger than the setpoint val-
ue, the red arrow flashes (high). If the actual temperature corresponds with the setpoint temper-
ature, the green bar illuminates. Should the actual surface temperature of the heating plate not
correspond with the actual temperature indicated, it is possible to enter an "offset". To define the
offset, press and hold the
F key, then press the
value as required. To save the new settings, press and hold
appears in the display.
Warning! Do not change any other heating plate parameters!
Fkey until "_SP" is indicated in the display. The opera-
F key until "InP" appears in the display (approx. 7 sec.); release
F key as many times as required until "oFS" appears. Correct this
ENGLISH
F key until the actual value re-
17

Publicidad

Tabla de contenido
loading

Tabla de contenido