Ac Current Measurement; Resistance Measurement - KPS -PA40 Manual De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KPS-PA40 • Digital clamp meter
3 Connect the test lead tips in parallelwith the circuit to be measured.Be careful
not to touch any electrical conductors.
4 The polarity ofthe red lead connection will be indicated along with the volt-
age value
5 Read the measure result directly from the display.
AC Voltage Measurement
1 Insert the black and red test leads into the COM and
V
Hz input terminals respectively.
2 Set rotary switch at desired V~ position.
3 Connect the test lead tips in parallelwith the circuit to be measured.Be careful
not to touch any electrical conductors
4 Read the AC voltage value from LCD display.
5 When measuring AC voltage, pushing Hz% button, the frequency of ACV will
show on LCD display.
DC Current Measurement
1 Set the rotary switch at desired 400A or 1000A position.
2 Push the SELECT button to select DC current.
3 Push the "Δ ZERO" button to get relative measurement mode and "0000"
show on LCD display.
4 Press the trigger to open transformer jaw and to clamp one conductor
only,making sure that the jaw is firmly closed around the conductor.
5 Read current value on LCD display.
NOTE:
As the jaw core may remain some magnetic force after using for awhile.If the
display can not reach "0" open the jaws severaltimes. Then work again

AC CURRENT MEASUREMENT

1 Set the rotary switch at desired 400Aor 1000A position.
2 Push the SELECT button to select AC current.
3 Press the trigger to open transformer jaw and to clamp one conductor
only,making sure that the jaw is firmly closed around the conductor.
4 Read the measure result directly from the display

RESISTANCE MEASUREMENT

11nsert the black and red test leads into the COM and
V Ω
Hz Input terminals respectively.