Installation Of The Water Connections; Olsberg Equipment; Installation Unit; Temperature Difference Controller - Olsberg Nevado Aqua Compact Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation of the water connections

TAS
inlet
1/2"
Return
flow heater
3/4"
● The water pipes can be laid through the floor or
through the back panel. When connecting the pipes
at the rear, the prestamped holes in the paneling for
water connections should be punched out.
● A pipe disconnector must be fitted in the cold wa-
ter pipe leading to the TAS due to the fact that the
standing water in the TAS inlet is „stagnant".
● After installing the water connections vent the sys-
tem at the ventilating valve of the stove. For this pur-
pose, unscrew the closure plate behind the combus-
tion chamber door under the top cover (Fig. 4).
Fig. 4 Ventilating valve
● Check all water connections on the stove for leaks.
● Screw the paneling for water connections on the
back panel.
18
TAS
exit
1/2"
Heating
inlet
3/4"

Olsberg Equipment

Installation unit

The return flow booster valve is integrated and set to
55°C.
Outlet from
the stove
Return
to the
stove

Temperature Difference Controller

The "Temperature Difference Controller" regulates the
circulation pump independently of the water tempera-
ture. This ensures the circulation pump only runs when
the water temperature in the oven is higher than in the
buffer tank.
2 Pt1000 temperature sensors are included in delivery.
These sensors are positioned in the sensor pockets of
the oven's water heat exchanger and buffer tank.
The assembly and installation of the "Temperature
Difference Controller" should be completed in accord-
ance with the separate instructions provided with the
device.
Inlet to the
buffer tank
Return
from the
buffer tank

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

23/638

Tabla de contenido