Combustion Air Slide Valve; Regulation Of Combustion Air; Fire Grate; Heat-Up Flap - Olsberg Nevado Aqua Compact Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Combustion air slide valve

Operating lever for combustion air supply
● Operating lever on „0":
all slide valves closed
● Operating lever on „I":
Secondary air slide valve completely open /
Primary air slide valve completely closed
● Operating lever on „II":
Secondary air slide valve completely open /
Primary air slide valve completely open

Regulation of combustion air

Position of operating lever:
„II" ..Ignition position, max. heat output
„I" ...Nominal heat output with billet wood
„I" ...Nominal heat output with wood briquettes
„I" - „II"..Nominal heat output with lignite briquettes
„0" ..Obtain glow
● As the secondary air also contributes to the cleanli-
ness of the glass pane, the operating lever should be
set on "I" minimum. This also applies in the event of
low-load operation.
● When not operating the lever should be set on "0", to
reduce the cooling down of the room.
20

Fire grate

Operating lever for the fire grate
● With the help of the operating lever the fire grate can
be opened or closed to move the ash from the com-
bustion chamber to the ash pan by pushing the fire
grate back and forth.
● Primary air can only enter the combustion chamber
if the fire grate is set on open position (operating le-
ver pulled forward).
Heat­up flap
Operating lever for the heat-up flap
The device is equipped with a heat-up flap. In heat-
up position, for faster heat-up of the device to optimal
operating temperature, the water – heat exchanger is
partially switched off. In addition, faster heating up of
the room in which the device is installed is achieved.
... Heat up position
... Maximum water capacity

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

23/638

Tabla de contenido