NOTE: Quick programming conditions:
- Transmitter memory empty
- Autoset never run previously.
- Only valid with ARC (Advanced Rolling Code) transmitters
If you make a mistake during the quick programming procedure, you can disconnect the power supply and restart the procedure.
Quick programming steps
1 - Unlock the gate manually, put it in closed position with the relative end stop enabled, and lock the gate.
2 - Supply mains voltage.
3 - The flashing light turns on (make sure it is connected).
4 - The system starts saving the transmitters automatically and the control unit is put on hold, waiting for a transmitter.
To skip the quick programming step and proceed with manual programming press + and - (ESC) simultaneously.
5 - On display starts flashing the message TX00.
6 - Press the hidden key of the transmitter to be saved.
7 - PUSH appears on the display.
8 - Press the key you want to associate with the receiver.
9 - TX01 appears on the display (if the second transmitter TX02 is present).
10 - Repeat steps 6 and 7 for the subsequent transmitters to store, up to 99, checking the increase on the display (example TX15).
11 - To go to the next autoset step, press the key of a previously memorised transmitter until AUTO appears on the display.
12 - The message AUTO appears on display and the gate automatically performs 3 manoeuvres by calculating the optimal opera-
ting parameters. If the autoset operation has been completed successfully, the gate stops in open position and the message OK
appears on display.
The maximum time for programming the first transmitter is 60 seconds.
If necessary, proceed with the manual setup of PARAMETERS and LOGIC, depending on the type of installation.
The radio receiver in this product is compatible only with the new ARC (Advanced Rolling Code) transmitters which, thanks to 128-bit encryption ensure
superior copy-security.
Storing new ARC transmitters is quite similar to that of normal rolling code transmitters with HCS coding
1) DESCRIPTION AND INTENDED USE
Gear motor 24Vdc for heavy-duty sliding gates up to 1500 Kg for residential or industrial buildings, with built-in controller CP.B1524
We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the
Benincà products and accessories and the guide for compiling the technical file and documents required under Annex V of the Machinery Directive,
mandatory under the regulations in force..
2) SPECIFICATIONS
Motor power supply
Consumption
Thrust
Operating jogging
Protection level
Operating temperature
Gate max. weight
Rack module
Opening speed
Noise level
Lubrication
N° of storable TX
Central control
Weight
3) PRELIMINARY CHECKS
Before proceeding with installation, check the following:
- The structure (gate, pillar, guide rail) must be sturdy and stable.
- The guide rail and its wheels must be suitably sized and maintained to avoid excess friction during gate sliding.
- If available, check the CE declaration of conformity of the gate and perform the risk analysis according to the machinery directive.
- Check that the gate travel during opening/ closing is limited by sturdy mechanical stops.
22
QUICK PROGRAMMING
ARC CONTROL UNIT
IMPORTANT, PLEASE READ CAREFULLY:
BULL 1524/BULL 1524.S
100÷250 Vac
1,7 A
24 Nm
intensive use
IP44
-20°C / +50°C
1500 kg
M4/M6 accessory - RI.P6
13,7 m/min
<70 dB
GREASE
2048
CP.1524
15,7 kg