6. Product Information
6.2 Technical specification
Type/Model
Footprint
Height
Lift
Weight
Supply voltage (primary)
Control board
Type of protection
Lifting speed
Built-in transformer power
Duty cycle
Permanent noise level
max. current drain (primary)
max. power consumption
Primary fuse
Ambient temperature
max. compressive/tensile force
Torque loading (dynamic)
Bracing moment (static)
44
510 -710 mm (see maker's plate)
300 -500 mm (see maker's plate)
24V - 230V AC 50/60 Hz
With entire surface and cover without drilled holes, the stand and
application surfaces achieve the protection class IP 30. Installation of
the RK SyncFlex adapter plates achieve the protection class IP 20.
max. 8-13 mm/s (see maker's plate)
(1.5 minutes operation/8.5 minutes pause)
3000 N/1500 N (see maker's plate)
RKPowerlift M
190 ×150 mm (L × W)
13 kg
Memory/Synchro
75 VA
15% for 10 minutes
< 60 dB (A)
1.0A (230V AC)
120W
6.3 A/T 230V AC
+10°C to +40°C
Mmax. 200 Nm
Mmax. 400 Nm