7.14 Settings table (configuration)

All the settings which you can perform on lifting columns are described in the following table.
Read 7.13 onwards for instructions on how to perform the settings.
Code
Determine the addresses of the connected drives:
0 = Off (if the drive is used individually)
113
1 = Master (address of the first drive)
2-8 = Slave (address of the other connected drives)
123
Set the number of slave controls in the bus system.
Set the base height of the retracted drive. The display on the hand switch then shows the base
133
height.
Parameter 213 must be switched from percentage to milimetre display prior to this.
Start initialisation: start initialisation run without having previously disconnected the mains plug of
211
the drive.
Height indication in the display:
Setting = 0 -> Height is displayed in the display in percent ("xxxP.").
213
Stroke length in mm -> Display shows the stroke moved.
If parameter 133 has a base height set, the hand switch display shows the total of the base height
and the stroke moved.
Changing the position of the decimal point of the height indication in the display:
.xxxx
xxxx.
311
xxx.x
xx.xx
Description
7. Working life
61