7. Working life

7.13 Install settings (configuration)

Use configuration to install the settings on the lifting column. You can, for example, determine
the addresses for the interconnected lifting columns. The possible settings are explained in the ta-
ble in 7.14.
Settings may only be adjusted if the lifting columns are at rest.

7.13.1 Basic configuration procedure

You must first enter an access code via the hand switch keypad and then a 3-digit code before
you can adjust the desired setting.
The access code must only be entered once and is then fixed until the mains plug is pulled out.
All entries must be made within 5 seconds, because the [lifting column] then quits configuration.
To store a setting, the F key must be pressed.
Press the F key three times (see section 7.7). If the access code has still not been entered,
"PArA" appears in the display.
Enter the access code 13121.
6-key handswitch: Press the keys in this sequence: I - III - I - II - I
8-key remote hand switch: Press the keys in this sequence: 1-3-1-2-1
If the access code has been entered correctly, "P---" appears in the display.
Now use the hand switch to enter the 3-digit code (e.g. 213 for the height indication) in order
to install the desired setting.
Install the setting by pressing the UP and DOWN
Press the F key to store the setting. To quit configuration, press the F key again or wait for 5
seconds.