Descargar Imprimir esta página

Performance Data Sheets; Interior Water Filtration System - Sears Kenmore 596.4679412 Manual De Uso

Publicidad

Idiomas disponibles

Idiomas disponibles

PERFORMANCE DATA SHEETS
@
Interior Water Filtration System
Model 46 9006-750
Capacity
750 Gallons
(2839 Liters)
System tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the
reduction
of Chlorine Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead, Mercury, Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts, Turbidity, Asbestos,
Tetrachloroethylene
and Lindane.
This system has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction of the substances listed below. The
concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.00 mg/L
2.0 mg/L _+10%
0.06 mg/L
0.050625 mg/L
97.00%
97.52%
Particulate Class I*
85% reduction
14,000,000 #/mL
Atparticles/mLleast
10,000
370,000 #/mL**
196,666 #/mL
97.40%
99.00%
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
91.70%
95.00%
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0018 mg/L
0.00073 mg/L
69.20%
88.10%
Benzene
0.005 mg/L
0.0133 mg/L
0.015 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
96.10%
96.30%
p-Dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>99.80%
>99.80%
Carbofuran
0.040 mg/L
0.0753 mg/L
0.08 mg/L _+10%
0.027 mg/L
0.008 mg/L
64.60%
73.45%
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001 mg/L
< 0.001 mg/L
>93.3%
>93.3%
Atrazine
0.003 mg/L
0.0102 mg/L
0.009 mg/L _+10%
0.0027 mg/L
0.00105 mg/L
76.30%
89.40%
Asbestos
>99%
126.5 MF/L
107to 108fibers/U _
< 0.17 MF/L
< 0.17 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
122,500 #/L
50,000/L min.
< 1 #/U
< 1 #/U
>99.99%
>99.99%
Turbidity
0.5 NTU
10.5 NTU
11 _+1 NTU
0.30 NTU
0.125 NTU
97.30%
98.80%
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 _+10%
< 0.00016 mg/L
0.000035 mg/L
91.80%
97.90%
Tetrachloroethylene
0.005 mg/L
0.015 mg/L
0.015 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>96.6%
>96.6%
Test Parameters: pH = 7.5 4- 0.5 unless otherwise noted.
4- 5°F (20°C 4- 3°C).
Flow = 0.78
gpm
(2.9 Lpm). Pressure
= 60 psig (413.7
kPa). Temp. = 68°F
It is essential that operational,
maintenance,
and filter
replacement
requirements be carried out for the product to
perform as advertised.
The disposable water filter should be replaced at least every
6 months.
Refer to the "Water
Filtration System" section for the
Manufacturer's
name and telephone number.
Refer to the "Warranty"
section for the Manufacturer's
limited warranty.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
Water
Supply
When 90% of the filter's rated life is used, the yellow
Water
Pressure
(Order) light comes on. When 100% of the filter's rated life
Water
Temperature
is used, the red (Replace) light comes on, and it is
Service Flow Rate
recommended
that you replace the filter. For models without
filter status lights, replace the filter every 6 months. Use
replacement
filter model 46 9006-750.
2010 suggested
retail price of $44.99
U.S.A./S49.95
Canada. Prices are
subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate
disinfection
before or
after the system. Systems certified
for cyst reduction may be
used on disinfected
waters that may contain filterable
cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
tThese contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
ttFibers greater than 10 um in length
_Basedon the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
Application Guidelines/Water
Supply Parameters
City or Well
35 - 120 psi (241 - 827 kPa)
33 ° _ IO0°F (1 ° _38°C)
0.78 gpm (2.9 L/min.) @ 60 psi
23

Publicidad

loading