Model P5WB2L/P4RFKB2/P4RFKB12 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Live Cysts
99.95%
Asbestos
99%
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2,4 - D
0.07 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
Use replacement filter P4RFKB2/P4RFKB12, part #9930.
2014 suggested retail price of $49.99 U.S.A./$59.99 Canada. Prices
are subject to change without notice.
Style 1 – When the water filter status display changes from "GOOD"
to "ORDER," order a new filter. When the filter indicator reads
"REPLACE," it is recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow, order
a new filter. When the indicator changes from yellow to red, it is
recommended that you replace the filter.
Style 3 – When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you replace the
filter.
After changing the water filter, flush the water system. See "Water
and Ice Dispensers."
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and local
laws and regulations.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters
that may contain filterable cysts.
Class I particle size: >0.5 to <1 um
*
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
**
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
††
® NSF is a registered trademark of NSF International.

PERFORMANCE DATA SHEET

Water Filtration System
System tested and certified by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine Taste and Odor, and Particulate Class I*; and against NSF/
ANSI Standard 53 for the reduction of Live Cysts, Asbestos, Lead, Lindane,
Toxaphene, Atrazine, and 2,4 ­ D.
Average
Influent Challenge Concentration
Influent
2.0 mg/L
2.0 mg/L ± 10%
7,300,000 #/mL
At least 10,000 particles/mL
Average
Influent Challenge Concentration
Influent
160,000/L
50,000/L min.
87 MFL
10
7
to 10
0.160 mg/L
0.15 mg/L ± 10%
0.140 mg/L
0.15 mg/L ± 10%
0.0019 mg/L
0.002 mg/L ± 10%
0.014 mg/L
0.015 mg/L ± 10%
0.0094 mg/L
0.009 mg/L ± 10%
0.220 mg/L
0.210 mg/L ± 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL
Maximum
Effluent
54/L
8
fibers/L
††
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
Refer to the "Warranty" section in this Use & Care Guide for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section in this Use & Care Guide for the
Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
97
97.2
**
99
99.4
Minimum %
Average %
Reduction
Reduction
99.97
99.99
99
99
99.4
99.4
98.6
98.6
98.9
99
93
93
94.5
94.7
87.5
96.1
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore elite 106.51773