Operating Instructions SATAjet 3000 B RP/HVLP (DIGITAL)
EN
6.4.2
Additional notes concerning the electronic
pressure gauge
The electronic pressure measurement system has been type-tested. It is
developed, designed and produced in compliance with the EU Directive
2014/34/EU. It has been classified according to II 2 G Ex ia IIC T4 FM
Global IS CL I, ZN 1, AEx ia IIC T4 IS CL I, DIV 1, GP A, B, C&D, T4 and
may be used and stored in the explosive zones 1 and 2 up to 60°C ambi-
ent temperature. Inspection authority: KEMA 05 ATEX 1090 X.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery exchange in explosive areas!
• Removal of the front cover of the pressure display!
• Installation of a battery other than the CR 1632 Renata!
When exchanging the battery, it is recommended to also replace the
sealing of the battery compartment!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use a compressed air connection G 1/4 a or a fitting SATA connection
nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
114
Warning! Risk of explosion!
Warning! Risk of explosion!
Note!