Conexiones En El Tablero De Bornes; Electrical Connections - motormatic CT-2-24 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
INSTALLATION
It is suitable to read the instructions attentively before the installation is carried
out.The non observance of the above-mentioned instructions, the improper
use or a wrong connection could compromise the safety or the correct device
operating and then the whole system working.
We accept no responsibility for any mal-operating and/or due damages
resulting from their inobservance.
Company aims to bring improving modifications to the product.
The equipment installation has to get carried out "to a fine art" only by qualified
personnel in compliance with the laws in force, following laws EN 12453 and EN 12445
regarding safety of automations.
Calculate disconnection elements into the power supply system somewhere within
reach.

ELECTRICAL CONNECTIONS

To grant the operator safety and to prevent any components damages, the control
unit must absolutely have no power supply during the connections.
Keep the power supply cables separate from the control cables.
For the supply cables, motor lines, flashing lights line/courtesy light, electric lock, use a
cable with min. section of 1,5 mmq.; For the auxiliary supplies, the safety controls and
contacts, a min. section of 0,5 mmq. Whenever the control cables are very long (over
30 metres), it is advisable to decouple by relay at the actual control unit.
Whenever a fuse blows, after having removed the cause, replace with a new fuse that
has the same characteristics. Install the safety devices, limit switch, photocells, sensitive
band, stop button.
If one or more safety devices are not installed, connect the relative terminals with the
controls common by means of a jumper.
All the N.C. contacts coupled to the same input have to be connected in series.
All the N.A. contacts coupled to the same input have to be connected in parallel.
An external, independent isolatin switch (not supplied)should be installed for the power
supply of control unit
No !
9
24V
Min. 2x1,5 mmq.
Encoder Min.3x0,5 mmq.
Ok

CONEXIONES EN EL TABLERO DE BORNES

4
Entrada antena
3
Salida 2º canal
16
Entrada mandos Común
12+16
Entrada para mando stop
13+6
Entrada 1 para dispositivos de seguridad Células fotoeléctricas o bordes de seguridad
11+6
Entrada 2 para dispositivos de seguridad Células Fotoeléctricas o bordes de seguridad
6
Entrada mandos común
6+8
Entrada para funcionamiento cíclico | abre stop - cierra
6+10
Entrada para mando de cierre
6+9
Entrada para mando de apertura
6+7
Entrada para mando peatonal
17
Salida 24 Vcc para alimentación de servicios (foto, radio etc. Máximo 500mA)
31
Salida para control de células fotoeléctricas "TEST"
30+18
Salida para cerradura eléctrica 12 Vcc máx. 1,5 A
30+ 2
Salida testigo luminoso de puerta de acceso abierta
30+21
Salida intermitente, máx. 20 W
30
Común para las salidas
32
Pulsador de paso a paso
33
Módulo radio
5
Predisposición para placa de radio
24
Trimer de regulación tiempo de pausa
27
Trimer de regulación fuerza de embrague
28
Entrada codificador M2 ( + - alimentación codificador)
29
Entrada codificador M1 ( + - alimentación codificador)
23
Dip switch
34
Entrada alimentación placa 24 Vac
8
E

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ct-2-24s

Tabla de contenido