Electrical
9
Disconnect
power before working
on pump, motor, pressure switch, or wiring.
MOTOR
SWITCH
SETTINGS
NOTE:
1/2 HP motors
are wired
for 115 volts only, and have no motor wiring
to change.
3/4 HP or 1 HP motor termina]
boards (located
under the motor end cover)
shou]d
]ook like the one below.
If the motor can operate
at either
115 or 230 volts,
it is set at the factory
to 230 volts. Do not change
motor wiring
if line voltage
is 230 volts, or if you have a single voltage
motor.
F
lg. CAUTION
I Never wire a 115 volt motor to a 230 volt line.
i
Dial Type Voltage
Selector
Voltage is factory set to 230 volts. To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise
until 115 shows in
the dial window as shown in Figure 15.
3. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 14.
4. Attach the ground wire to the grounding connections
as shown in Figure 14.
5. If there are other wires, they should be capped.
6. Reinstall the Motor end cover.
Power Supply Connections
Ground Wire Connection
Figure 14:Voltage
set to 230 volts, Dial Type
Figure 15:Voltage
set to 115 volts, DiaI Type