10
SUPPLEMENTARY INSTRUCTIONS FOR SAFE
USE (NORMAL OPERATION WITH NO
OPERATOR INTERVENTION)
10.1
Keep Enclosures Closed During Use
10.1.1
Transmitter
Verify the following:
10.1.2
Sensor Head
Verify the following:
10.2
Periodic Inspections
Include the sonar process monitoring system in periodic inspections of
the facility.
10.2.1
Transmitter Inspections
Verify the absence of the following:
20909-01C Rev 06
• The transmitter cover should be tightly closed and all 4 screws
installed to secure the cover.
• Cable glands should be properly installed and snug in their
mounting holes in the enclosure and snug around their cables.
• Cables shall be prevented from applying pulling or twisting
forces on the cable glands.
• All sensor head latches should be snugly mated.
• Clamps should be snugly installed on the boot seals.
• The cable connector shall be snugly latched onto the mating
connector.
• The cable shall be installed with a drip loop (if necessary) such
that water will not run along the cable toward the connector
• The cable shall be installed such that the connector will not be
subjected to twisting or pulling forces.
• Loose hardware or fittings
• Damage to enclosure
• Damage to seals
• Dirt or moisture inside enclosure
Page 10-1