LEDs colour
Green
The torque and the angle are inside the programmed limits.
Yellow
The minimum torque value has not been exceeded. The screw has
undergone no stress, the tightening operation has been stopped too
soon.
Yellow + red
The torque and angle results are near the desired values. The screw
has undergone no stress.
Red
The torque has reached the disassembly limit (assembly damage
limit) or the angle is greater than the maximum angle when the
torque is correct. There is a great risk that the screw has undergone
permanent strain.

1.2 - Buzzer

At the end of each tightening, a sound informs the operator of the tightening result:
1 beep -> tightening correct
2 beeps -> tightening not correct or faulty operation
3 beeps -> end of tightening sequence ("Data Transfer Unit" only)
Each user will estimate if these sounds are useful for him/her. They can be disabled separately using the CVIP software (see
"CVIP Poket software" manual).

1.3 - Display

At the end of each tightening, alternatively torque, angle (TA version) and possible faulty operations are displayed.

1.3.1 - Tightening results

Tightening correct
Angle high

1.3.2 - Faulty operations

Faulty operations are coded so that the operator can efficiently locate the default. To know the signification of each code, see
"ERROR TABLE," page 16.

2 - TIGHTENING RESULTS ON THE PDA

When the CVIP software is installed on the PDA and when the Bluetooth communication is initialised, you can read the tighten-
ing result:
overall result,
torque value (reminder of minimum and maximum tolerances),
angle value (reminder of minimum and maximum tolerances).
This function is used to compare tool results with a reference torquemeter, particularly in tightening adjustment. Results are not
stored in the PDA. For further information, refer to "CVIP Poket software" manual.
Interpretation
Torque low
Torque > disassembly limit
EAP/EDP
None (tightening correct)
The
again.
The operator can unscrew then
tighten the assembly again.
Loosen the assembly and
repair
Torque high
Approach unfinished
Action
operator
can
tighten
Angle low
Overspeed