1 - MAINTENANCE LIGHT

The tool is fitted with a maintenance alarm which goes on as soon as the tool has performed a
programmed number of cycles. This means that it is time to perform maintenance operation.
This alarm does not stop the tool, the operator can go on working but he/she is to inform the main-
tenance department.
The number of cycles is set to 250,000 by default; it can be modified using CVIP Pocket software.
However, you are advised to perform the following operations:
LEVEL 1
Cycles
Replace Angle Head
Pinion - KIT 17
500 000
1 000 000
1 500 000
2 000 000
2 500 000
3 000 000
When the maintenance operation is done, reset the counter using the CVIP software in order to turn off the light.

2 - TORQUE TRANSDUCER CALIBRATION

The tool can be only calibrated using the CVIP Pocket software (see corresponding manual).

3 - ERRORS

In the case of tool faulty operation, error codes are displayed. These error codes can also be read on the CVIP Pocket result screen,
which specifies the error type plaintext.
For further information, see "ERROR TABLE", page 16.
You can find an error log in chronological order in the PDA's "Maintenance" menu.

4 - TOOL OVERVIEW

For disassembly and part replacement, see "PART LIST", page 21.

5 - ELECTRICAL CONNECTIONS

See "PART LIST", page 21.
EAP/EDP

CHAPTER 6 - MAINTENANCE

LEVEL 2
Replace keypad-KIT 3
Replace protection-KIT 14
LEVEL 3
Replace planetary
reduction gears-KIT 12
Part no
6159936431
Issue no
06
Language English
Date
09/2009
24
Page
15 /
CALIBRATION

Publicidad

Tabla de contenido
loading