Important
The connection must be made by authorised,
skilled personnel, in accordance with the re-
levant legal requirements, using appropriate
and specifi ed materials.
The appliance is supplied with operating vol-
tage 230V1~N 50 Hz.
For direct connection to the mains one must en-
visage a device that ensures disconnection from
the mains, with a contacts opening distance
that ensures complete disconnection in the con-
ditions of category III over-tension, in complian-
ce with the installation rules.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
If not already present, install an automatic
1)
circuit-breaker
, close to the appliance, with
(A)
the following characteristics:
B
D
3320090_inst_GB_rev.1
ELECTRICAL CONNECTION
C
E
C
– Thermal breaker device (to adjust see table An-
nexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at a 30 mA.
Pull off the knob (B).
2)
Take out the screws(C) and take down the
3)
dashboard (D) to access the electric box (E).
Undo the screws(F) to remove the lid (G).
4)
Connect the automatic circuit-breaker (A) to
5)
the appliance's terminal board
electrical mains supply, in accordance with
the electrical system diagram provided at the
back of the manual and using a cable with the
following characteristics:
– Weight: ≥ thanH05RN-F type (designation 245
IEC 57).
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Replace all when the operation is complete.
6)
- 11 -
and to the
(H)
A
G
F
GB
H
ENGLISH