Fitting the mechanical sensor and relative support (if available)
- Fasten the external sensor support to the wheel balancer body using the three screws
supplied with the machine (A, fig.6a);
- Insert the external sensor pin (B, fig.6a) in the sensor support bush (C, fig.6a);
- Screw the screw (D, fig.6a) bringing it closer to the sensor pin without touching it;
- Make sure that the external sensor rotates freely;
- Connect one of the sensor's cable connectors to the socket located on the sensor body
(H, fig. 6);
- Tape the cable to the sensor support (F, fig. 6a) so that it is never tensioned;
- Connect the sensor cable connector to the machine's rear panel (G, fig.6a).
IMPORTANT: after installing the external sensor, calibrate the sensor as described in
the paragraph "Width sensor calibration".
The machine is to be fixed to the ground if:
- it does not have the accessory triangular foot;
- if it does have the accessory triangular foot but is going to be used with wheels heavier
than 50Kg. In such a case the triangular foot will have to be removed in order to fix the
front bracket;
- undo the three M8x60 hex head
screws fastening the machine to the
pallet;
- remove the plastic washers from
between the body and the three L
shaped brackets: These brackets
are used to fix the machine to the
ground;
- refit the brackets as originally
mounted on the machine, without
tightening the screws;
- move the machine into the selected
position on the floor, ensuring that
the minimum distances indicated
72
6
Fixing machine to ground (Fig. 8)
Operator's manual EM 9280 - EM 9280 C CompactLine
6a
7