- Keep the arm in contact with the rim until the machine has acquired the wheel's diameter
and distance values. The following screen appears during this phase:
- if only one measurement is taken, the machine interprets the presence of a rim with balanc-
ing using a clip weight on both sides (Dynamic Balancing Programme);
- moving the arm to the rest position, the machine will set up for the manual WIDTH entry;
- in this phase, it is possible to perform an additional acquisition of the rim diameter and
distance.
- Measure the width of the rim using the provided calliper (Fig. 13).
- Change the displayed width value by increasing or decreasing the value using the keypad.
Operator's manual EM 9280 - EM 9280 C CompactLine
13
UK
87