Installation
6.5.1
T e rminal diagram
1
Main fuse
Fuse for motorized ball valve
3
CD degassing control valve
4
Group message
5
Optional for conductivity
6
Ball control valve
(correcting variable (25) / Return value (46))
7

RS-485 interface

8
---
T e rminal
S ignal
number
1
PE
230 V power supply via mains
2
N
cable and plug.
3
L
4
PE
5N
N
"PU" pump
6 M1
M 1
7
Y2
8
N
CD degassing control valve
9
PE
10
Y 1
11
N
WV make-up valve
12
PE
13
COM
14
NC
Group message (floating).
15
NO
16
Not assigned
External make-up demand from
Make-up (230
17
a pressurisation station;
V)
controller must be set to
Make-up (230
18
"Levelcontrol"!
V)
19
PE shield
Level analogue input, not used
20
- Level (signal)
by the device.
21
+ Level (+ 18 V)
22
PE (shield)
- Pressure
23
(signal)
Pressure analogue input
+ Pressure (+
24
18 V)
0 – 10 V
25
(correcting
variable)
0 – 10 V
26
Ball control valve
(feedback)
27
GND
28
+ 24 V (supply)
29
A +
RS-485 interface.
30 — English
F unction
Wiring
Pre-wired
Pre-wired
Pre-wired
Pre-wired
User,
optional
User,
optional
---
Pre-wired
Pre-wired
User,
Vacuum spray degassing — 24.04.2020 - Rev. A
9
Digital inputs:
Water meter; Insufficient water
10
Ball control valve (supply)
11
Pressure analogue input
12
External make-up demand (Levelcontrol only)
13
WV make-up valve
14
Pump
15
Mains supply
T e rminal
S ignal
number
30
B -
31
GND
Insufficient water switch - dry-
+ 24 V
32
running protection
Contact water meter, for
evaluation of the make-up,
33
E1
terminal 32/33 closed = meter
pulse.
Insufficient water switch, contact
32/34. Lead the cable of the
insufficient water switch through
34
E2
the cable gland and connect at
the terminals
6.5.2
RS -485 interface
6.5.2.1
Connecting the RS-485 interface
Connect the interface as follows:
1.
For connecting the interface use only a cable with these properties:
LJYCY (TP), 4 × 2 × 0.8, maximum overall bus length 1000 m.
2.
Use a shielded cable to connect the interface to terminals 29, 30, 31 of the
main board in the control cabinet.
For connecting the interface, see chapter 6.5 "Elektrischer Anschluss"
on page 10 .
3.
When using the device with a control centre not supporting an RS-485
interface (RS-232, for example), you must use a corresponding adapter.
F unction
Wiring
optional
Pre-wired
User,
optional
Pre-wired