Connection Of Control Elements - Vimar ELVOX EN05 Instrucciones De Montaje Y De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 82
6.5

Connection of control elements

Caution!
Danger of electric shock:
Before any cabling works begin, it must be ensured that the cables are disconnected from the power supply.
During cabling works, it must be ensured that the cables remain disconnected from the power supply at all times (e.g. prevent reconnection).
Attention!
In order to avoid damaging the controls:
-
The local safety regulations must be complied with at all times.
-
It is very important that mains cables are laid separately from control cables.
-
The controls voltage must be 24 V DC.
-
If external voltages are applied at terminals XP020, XB10 or XB01, the entire electronic system will be destroyed.
-
Only potential-free normally open contacts may be connected to terminals 1 and 2 (XB01) .
-
The shorting plug should never be plugged into the XP020 system socket!
Connecting possibilities.
Reference:
When installing external control elements, or safety and signal equipment, the relevant instructions must be observed.
Advice:
Before connecting a control element to the terminals with system sockets, the corresponding shorting plug must first be removed.
Terminal XB01: It is possible to connect an external con-
trol (selector or push-button) or photocells
Connection of the ELVOX photocell to XB01
Label
Type / function
1
COM, -
2
N.C. (contact) or N.O. (contact) 8.2 / Level 5
3
-
Reference:
Once the ELVOX photocell is connected, the programmable impulse input must be
programmed to the function C1 (drive system stops and reverses).
Programming of the photocell is described in chapter 8.2 / menu 5.
EN
Label
XB01
XB10
XP020
Label
Type / function
1
GND connection
2
Programmable impulse input
3
+ 24 V DC connection (max. 50 mA)
70
Has no function
71
Has no function
S1
Connection example: External impulse button
- plug XP020: it is possible to incorporate an additional NC contact (op-
tional), type EN0C, to enable the use of an external control (selector or
push-button) and photocells (24V supply voltage).
-
-
Type / function
Connection of external con-
6.5 / 2
trol elements without system
cabling and two-wire photo-
cell
Not in use
-
Terminal for N.C. contact
-
Type EN0C (optional) for
addition of a second control
or photocell.
8.2 / Level 5
-
-
-
8.2 / Level 5
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox en10

Tabla de contenido