8.3
Functions overview for the levels
Caution!
Important factory default settings can be changed using the extended functions.
All the parameters must be set correctly to avoid damage to persons or property.
Level 1 – Basic functions
Menu 3: Intermediate position OPEN
"Intermediate position OPEN" – closing function is possible with automatic closing timer
Menu 4: Intermediate position CLOSE
Menu 5: Soft run position OPEN
Menu 6: Soft run position CLOSED
Menu 7: Relay output
Menu 8: RESET
Attention!
After a reset, all the parameters revert to the factory settings. In order to ensure that the controls operate properly:
- all the required functions must be re-programmed,
- the remote control unit must be re-programmed,
- the drive system must be driven once to the OPEN and CLOSED door positions.
Advice:
- Only the intermediate position that was programmed last can be used.
- If an automatic closing timer is activated (Level 3 / Menu 1), the relay output (Level 1 / Menu 7) cannot be programmed.
Reference:
If changes are made in Menus 3 to 6 in Level 1, a new learning run must be carried out for the automatic cut-out.
The learning run procedure is described in Section 7.5.1.
Menu 7: Relay output
A7- Drive system running / signal light is on
B7- Drive system running / signal light flashes
C7- 3-min. light
D7- Wiping impulse
E7- Malfunction
F7- Push-open security device
G7- Door position CLOSED
H7- Door position OPEN
EN
Set using the (+ / OPEN) and (- / CLOSE) buttons
Set using the (+ / OPEN) and (- / CLOSE) buttons
Set using the (+ / OPEN) and (- / CLOSE) buttons
Set using the (+ / OPEN) and (- / CLOSE) buttons
35