Vimar ELVOX EN05 Instrucciones De Montaje Y De Manejo página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 82
Level 2 – Operator settings
Menu 1: Required driving power OPEN (sensitivity in increments*)
Menu 2: Required driving power CLOSE (sensitivity in increments*)
Menu 3: Automatic cut-out OPEN (sensitivity in increments**)
OFF
Menu 4: Automatic cut-out CLOSE (sensitivity in increments**)
OFF
Menu 5: Speed OPEN (in increments)
Menu 6: Speed CLOSE (in increments)
Menu 7: Soft run speed OPEN (in increments)
Menu 8: Soft run speed CLOSE (in increments)
* The higher the setting, the higher the driving power.
** The lower the setting, the more sensitive the automatic cut-out.
Caution!
To exclude any risk of injury, the automatic cut-out (Menus 3 and 4) may only be switched to OFF if a photocell barrier or closing edge safety
device is installed.
Reference:
If changes are made in Menus 5, 6, 7 or 8 in Level 2, another learning run must be carried out for the automatic cut-out. The learning run pro-
cedure is described in Section 7.5.1.
Level 3 - Automatic closing timer
Menu 1: Automatic closing timer
Menu 3: Door open duration (in seconds)
Menu 4: Warning time (in seconds)
Menu 5: Start-up warning (in seconds)
Advice:
- The automatic closing timer can only be programmed if a photocell or a closing edge safety device is installed.
- The functions in Menu 1 can be altered as desired via the time settings in Menus 3, 4 and 5.
36
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox en10

Tabla de contenido