11.3.4 Error type E or F
1
2
3
4
9a
9b
Fig. 49: Error type E, diagram
1
2
3
4
5
Fig. 50: Error type F, diagram
6.0.0.0
E000
Fig. 51: Acknowledge error type E or F
84
Error type E (Fig. 49):
5
6
7
8
Error type F (Fig. 50):
If type E or F errors occur, proceed as follows to acknowledge (Fig. 51):
• To change to the menu mode, press the acknowledge button.
The menu number <6.0.0.0> flashes.
12.3
• Press the acknowledge button again.
The error is acknowledged and the status page is displayed.
NOTE
Once the cause of the error has been removed, the error will be auto-
matically acknowledged.
Program
Contents
step/query
1
• Error code is displayed
• Pump goes into emergency operation
2
• Error meter is increased
3
Error matrix AC or HV?
4
• SSM is activated
5
Error criterion fulfilled?
6
Error acknowledged?
7
Error matrix HV and > 30 minutes?
8
• SSM is activated
9a
End; auto control (double pump) will be continued
9b
End; auto control (single pump) will be continued
Yes
No
Program
Contents
step/query
1
• Error code is displayed
2
• Error meter is increased
3
Error criterion fulfilled?
4
Error acknowledged?
5
End; auto control is continued
Yes
No
04/2009