Step 5: Setting Programs To Stack Or Overlap; Step 6: Setting The Mv/Pump Start - Rain Bird ESP-MC Serie Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Programming the Controller,
5. Use the arrow keys to select a start time. Start
times are available in 15 minute intervals, with an
OFF setting available between the 11:45 pm and
12:00 am options on the 60 Hz model (and
between 23:45 and 24:00 on the 50 Hz model).
Note: Start times are displayed in chronological
order. If a start time is deleted by setting it to OFF,
all later start times are automatically moved down
one start time number. When a start time is added
to any start time number, the controller automatically
reorganizes the times so that times appear in
chronological order. This reorganization only occurs
after the dial has been moved off the WATERING
START TIMES position.
6. If you want to set additional start times, press MAN
START/ADV
to toggle back to the left side of the
display and the next available start time number. Set
the next start time in the same fashion as the first.
7. Return the dial to AUTO.
The controller returns to the time of day display.

Step 5: Setting Programs to Stack or Overlap

You can set a program to stack (run one at a time) or
overlap (run simultaneously). The controller can run
up to nine valves simultaneously. The default setting
is to stack all programs.
To set programs to stack or overlap,
1. Rotate the dial to PROGRAM OVERLAP.
The display shows the program and STACK or
OVERLAP.
18
continued
2. If the program you want is not displayed, press
PGM
until it is.
3. Use the arrow keys to set the program to either
STACK or OVERLAP.
4. Return the dial to AUTO.
The controller returns to the time of day display.

Step 6: Setting the MV/PUMP Start

The controller has two master valve terminals on its
circuit board. MV2 (master valve 2) is enabled when
any station operates. MV1 (master valve 1) can be
enabled or disabled for each individual station.
To set MV1 for a station,
1. Rotate the dial to MV PUMP START.
The display shows the station number and MV
ON or OFF. The station number is flashing,
indicating that it is ready to be set.
2. Use the arrow keys to select the station number.
3. Press MAN START/ADV
side of the display. The ON or OFF flashes,
indicating that it is ready to be set.
4. Press either the ON or OFF key.
5. If you want to set another station, press MAN
START/ADV
the display to continue setting stations.
6. When you are finished setting stations, return the
dial to AUTO.
The controller returns to the time of day display.
to toggle to the right
to toggle back to the left side of

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading