Recommended nozzle settings
■ High speed / less cleaning (with low pollution) Figure 7,8,9,10
■ Slow speed / high cleaning effi ciency (moderate to heavy
contamination) Figure 11,12,13
■ The above are recommending settings and operator can select a
proper nozzle direction based on above principle actual pool situation.
Brush installation
1
Press and install the brush into the
corresponding slot.
2
Make sure to install the brush tight.
Brush disassembling
1
Push out the brush bar from inside of
robot.
2
Take out the brush.
Tip:
Suggest not using the brush in case it will not help you clean the pool
(for example there is slope or too dirty on the pool fl oor).
Commissioning
Since you have made your settings, you can put the cleaner carefully
and slowly into the pool. Please refer to the following pictures as the
cleaner may be best placed in the pool. Figure 14,15,16
The cleaner must always be committed or removed to the pool that
the underside of the cleaner facing the pool wall, to avoid possible
scratches on the pool surface. Figure 17,18 Abbildung 17,18
IMPORTANT! Figure 19,20
Care and Maintenance
Cleaning the fi lter bag
Unfold the retaining ring and open the cleaner.
Figure 21,22
Press the buckle on the base of the cleaner and take off the fi lter
cartridge. Figure 23,24
Take off the fi lter bag, drain and clean it and put on the fi lter bag
again. Figure 25,26,27
Important
Please press the buckle to remove or restore the fi lter cartridge. If this is
not observed, it may cause damage to the lower part of the cleaner.
■ Press the buckle simultaneously. Figure 28
■ Do not pick up the two parts of the cartridge at the same time. Figure 29
10
■ The installation must be initiated from one side. Figure 30
■ Press the buckle. Figure 31
■ Press the buckle on the other side. Figure 32
■ Lift out the fi lter cartridge from one side. Figure 33
■ Install the fi lter cartridge. Figure 34
■ Remove the fi lter cartridge. Figure 35
Remove bzs. Assembly of the fi lter bag. Figure 36
Tips and advices
■ Each time the cleaner is removed from the water, the fi lter element
has to be cleaned.
■ The pH-value of the pool water must be between 7.0 - 7.4.
■ The water temperature must be between 10 ° C and 32 ° C.
■ After pressing the „power off" button, the "power on" button can't be
pressed for 30 seconds.
■ We recommend to keep the cleaner between 5 ° C and 40 ° C in a
shaded, well-ventilated place. The supply cable must be wound up for
storage. (The fl oat on the cable must not be moved, so that a perfect
swimming of the cable in the water is maintained) Avoid direct expo-
sure to the sun all the time!
■ Before using, please read the instruction for fault rectifi cation
thoroughly.
■ Keep the cleaner always on the handgrip to remove it in and out of
the pool.
Trouble Shooting
Symptom
Possible reason
The pool cleaner
turns while cleaning
the water (note, this
is normal).
Cable twists
Obstruction in pool.
or
The cable in the water
coils up.
is too long.
Connecting cable is
not long enough.
The cleaner
does
not reach all
The pool shape
pool area.
doesn't make a
complete cleaning
possible.
The water cycle of
the bath is switched
on.
Too much air in the
case.
The cleaner
does
not work.
A foreign object is
in/at drive.
061014_v1901
EN
Corrective action
Unplug power line,
complete the cable
and unscrew.
Remove obstruction in pool.
Get the excess part of
the cable from the water.
The cable in the water has
to be long enough to allow
the cleaner to reach all
corners of the bath.
Allow the cleaner to
reach all corners of the
bathroom, enter the
maximum length of the
connecting cable into the
pool, but consider a
corresponding minimum
distance of the control unit
to the pool.
Slide the pool cleaner
by hand to the places
where was not cleaned
and restart manually
backwards forwards.
Turn off the fi lter
pump.
Turn off the machine
and let all the air
escape.
Contact the service
center.