0x9F - Set power
Example for Remote Ctrl CMD ID 0x01:
reduction and
Query:
reactive power
(continued)
Start Length
Remote Ctrl Data
Values in the 'Remote Ctrl Data' byte:
P
P
Response:
Start Length
Remote Ctrl Data
-
-
-
Inverter-specific behaviour for Fronius IG Plus and Fronius CL:
For effective power specified values < 10%, the inverter switches to 'Forced Standby'
mode - no power is fed into the grid.
Device / Option Number
variable
0x00
Inverter number
Remote Ctrl Data
Reserved Separator
rel
0x00
0x7F
:
big endian | unsigned char | resolution: 1 LSB = 1 [%] | value range 0 to 100
rel
Device / Option Number
variable
0x00
Inverter number
'P
' provides the maximum effective power output by the inverter in relation to the
rel
nominal power of the inverter.
A 'P
' value of 100%, for example, means that the maximum effective power output
rel
by the inverter corresponds to the nominal power of the inverter - no limitations are
in effect.
A 'P
' value of 10%, for example, means that the maximum effective power output
rel
by the inverter corresponds to 10% of the nominal power of the inverter.
Command Remote Ctrl CMD ID Separator
0x00
0x9F
0x01
Checksum
Reserved
Reserved
Separator Reserved
0x00
0x7F
Command Remote Ctrl CMD ID
0x00
0x9F
0x01
Checksum
56
0x7F
0x00
Separator
0x7F