Vaillant VPV I Serie Instrucciones De Funcionamiento página 40

Ocultar thumbs Ver también para VPV I Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Appendix
Setting level
Power limiter
Fixed voltage
Factory setting
All parameters
Main menu → Settings → Service → Reactive power
Mode
Load Defaults ¹
Number of nodes ¹
Node 1 ¹
Node 2 ¹
Node n ¹ ²
Display curve
¹ Not displayed for cosPhi = 1 mode.
² Only displayed if a value > 2 has been set under Number of nodes.
38
Values
Unit
Increment, select, explanation
Min.
Max.
500
W
The inverter's output power can be manually
limited to a minimum of 500 W. If the power is
manually limited, the Derating symbol and the
Derating /Reason: User limit measured value
are displayed in the status display.
V
Password is queried.
Ask customer service.
The following settings can be configured:
→ Status
→ Value
This switches off automatic MPP tracking.
The input voltage can be set in 1 V increments in
the range between the maximum and minimum
input voltage.
Password is queried.
Ask customer service.
When you reset to the Factory setting, the fol-
lowing data is deleted:
- Yield data
- Event messages
- Date and time
- Country setting
- Display language
- Network settings
After resetting to the Factory setting, the unit
restarts and displays the guided initial start-up.
Under this menu item, the competent person can
change further ENS parameters.
Type of React. pwr. char. curve
The following selection options are available:
- cosPhi = 1
- Q(P)
- Q(U) linear
- Q(U) hysteresis
You can select the standard characteristic here.
- Q(P) > 3680 W
- Q(P) > 13,800 W
Setting Number of nodes
You can freely program a characteristic via the
grid points.
P (%) cannot be changed for the first and last grid
point (000%, 100%).
P (%) cannot be changed for the first and last grid
point (000%, 100%).
P (%) cannot be changed for the first and last grid
point (000%, 100%).
The previously set React. pwr. char. curve is
displayed.
Installation and maintenance instructions VPV I 0020273427_02
Default
setting

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Vpv i 1500/2Vpv i 2000/2Vpv i 2500/2Vpv i 3000/2Vpv i 4000/2