If the machine is double-fronted, fit the cone supports (9 Fig. 6) and fasten together with
the plates supplied (10 Fig. 6). To hook up the various modules, connect the cables (11
fig. 6) together (connect each cable to its counterpart) and secure them with the provided
ties. To connect the machine to the power supply, follow the instructions in the chapter
'Electrical and pneumatic hook-up'.
Additional modules may be installed on the base module to obtain various machine
compositions.
To build up machines with several modules, connect the add-on modules to the base
module in a number not exceeding the maximum permitted, which is:
- 48 single-sided/double-sided heads for the 6 head BRC1T
- 40 single-sided/double-sided heads for the 5 head BRC1T
- 60 single-sided/double-sided heads for the 6 head BR300
- 50 single-sided/double-sided heads for the 5 head BR300
ELECTRICAL AND PNEUMATIC HOOK-UP
WARNING
All operations required for the electrical hook-up of the machine must be carried out
exclusively by a qualified electrician.
- The electrical supply must be suitably sized in relation to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the power supply hook-up point, so that volt-
age drops under full load do not exceed 4% (10% in the case of start-up) below the
rated voltage specified on the dataplate.
- The user must equip the machine with the following:
• a dedicated power plug in compliance with the relevant electrical safety standards.
• a suitable circuit-breaker (residual current set to 30 mA) on the mains connection
• power line fuses in accordance with specifications in the main wiring diagram of this
manual.
• a suitable earthing system installed on the workshop mains line
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
panel and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
The standard version power supply is three-phase plus ground at 400V, 50/60 Hz (other
voltages available on request). The cross section of the power line wires will be based
on the machine's draw rating shown on the serial plate.
NOTE
The machine version equipped with the splicer accessory includes a pressure regulator
set to 6 bar (for standard machine use).
WARNING
An efficient grounding circuit is essential for safe and correct machine operation.
NEVER connect the grounding line to gas or water lines, to telephone wires, or to
other non-suitable objects.