4.3. Switching off (diagram A)
When the generating set is turned off, the motor continues to give off heat.
Appropriate ventilation should be provided after the generating set is turned off.
To stop the generating set urgently, place the engine switch on "O" (OFF).
Warning
Take the plugs out of the sockets and allow the engine to run without any charge for 1 to 2 minutes.
Place the engine switch (10) on "O" and the set will stop.
Close the fuel tap (14).
5. Safety features (if fitted, see specifications table)
5.1. Oil cut-out
This mechanism is designed to prevent any damage to the motor resulting from lack of oil in the motor sump. It automatically cuts out
the motor. If the motor stops and will not restart, check the motor oil level before looking for any other cause of the problem.

5.2. Circuit breaker

The electrical circuit of the set is protected by several magnetothermal, differential or thermal cut-out switches. Any overload and/or
short circuits cause the supply of electrical energy to be cut.

6. Maintenance schedule

6.1. Reminder of use

The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme.
However, it should be added that it is the environment in which the generating set is operating which determines this programme.
Accordingly, if the set is used in extreme conditions, shorter intervals between maintenance procedures should be adopted.
These maintenance schedules apply only to generating sets running on fuel and oil, that conform to the specifications given in this
booklet.

6.2. Maintenance table

carry out the maintenance procedures
part
Motor oil
Air filter
Spark plugs
Spark arrester
Sediment bowl
Cleaning the generating set
Valve clearance *
Fuel filter
Fuel
tank *
Battery
Fuel line
NB: * these procedures should be carried out by our registered agents
at whichever deadline
is reached first
Check the level
Change
Check
Clean
Check – clean
Clean
Clean
Check – adjust
Clean
Clean
Check
Check (replace if necessary)
*
Each time it is
Within the
used
1st month
or 20 hours
Every 3
Every 6
months or
months or
50 hours
100 hours
Monthly
Every 2 years
Every year
or 300
hours