Promax MO-180 Manual De Usuario página 147

Modulador sfn/mfn dvb-t/h
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. MO-180
Name
Message
*MIHd<cr>
MIH
*?MIH<cr>
*MILd<cr>
MIL
*?MIL<cr>
*MBWd<cr>
MBW
*?MBW<cr>
ERN
*?ERN<cr>
*ERC<cr>
ERC
*?ERLnn<cr>
ERL
*?LCK<cr>
LCK
*MIHd<cr>
MIH
*?MIH<cr>
*MILd<cr>
MIL
*?MIL<cr>
*MBWd<cr>
MBW
*?MBW<cr>
*MHId<cr>
MHI
*?MHI<cr>
Page 77
Answer
Description and Format
Sets the modulator HP TS Input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
*MIHd<cr>
Asks for the current modulator HP
TS input. 'd' as before
Sets the modulator LP TS input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
Asks for the current modulator HP
*MILd<cr>
TS input. 'd' as before
Sets the modulator output BW
'd' decimal digit
0: 8 MHz, 1: 7 MHz, 2: 6 MHz
*MBWd<cr>
Asks for the current modulator
output BW. 'd' as before
Retrieve the internal error counter.
*ERNnn...n<cr>
'nn...n' value using 8 decimal digits
(padding with '0' on the left)
Clear the internal error counter.
*ERLtext<cr>
Retrieve an error message
'nn' is the error index in decimal
value 'text' is the text string in ASCII
format
* LCKchhhh
Retrieve the locked status.
<cr>
'c' is the lock test result: 'L for
locked, 'U' for unlocked
'hhhh' is an hexadecimal value
corresponding to a status code (see
section 4.11 for error codes)
Sets the modulator HP TS Input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
*MIHd<cr>
Asks for the current modulator HP
TS input. 'd' as before
Sets the modulator LP TS input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
Asks for the current modulator HP
*MILd<cr>
TS input. 'd' as before
Sets the modulator output BW
'd' decimal digit
0: 8 MHz, 1: 7 MHz, 2: 6 MHz
*MBWd<cr>
Asks for the current modulator
output BW. 'd' as before
Sets the modulator hierarchy mode.
'd' decimal digit
0: NO, 1: α=1, 2: α=2, 3: α=4
*MHId<cr>
Asks
mode.'d' as before
for
the
current
hierarchy
04/2008

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido